{{n3data.header}} {{n3data.message}}
How To: Connect a Shell Cybera SCA-325 with a Verifone Commander CR and a DC401.
This applies to stores that have just installed a Cybera SCA-325 and removed the Verifone Zone Router.
  1. From the C-Store Office home page go to Data Entry > Dashboard.
  2. Scroll down to Station Options and click Cash Register.
  3. Select Advanced.
  4. Under DC LAN, enter the following settings:
    • Mode: Static
    • IP: 10.96.10.2
    • Mask: 255.255.255.0
    • Gateway: 0.0.0.0
    • CR Connection: Checked
  5. Lower on the page, under CR IP enter 192.168.31.11.
  6. Connect an ethernet cable from the LAN port on the DC401 into LAN 4 on the Cybera SCA-325.
  7. Check and see if you see a link light on Port 4 of the SCA-325.
    Note: If you don't see a link light, call Cybera and ask them to enable port 4 for back office.
The following final steps must be completed by a Petrosoft Tech. Please call Petrosoft technical support to complete the process.
  1. Sign into the DC401 via SSH.
  2. Edit the /etc/rc.local file.
    • Add route add 192.168.31.11 gw 10.96.10.1 to the last line of the file.
    • Save the file.
  3. Reboot the DC401.

Back Office 